Directions for Using Sampling Kits for Methanol Preserved Soils(Used
for analysis for Gasoline UST, BTEX+, or 8260+ List)
For each sample:
- Collect 10 cc of compacted soil in the plastic syringe coring device.
- Insert the soil into the 40 ml glass pre-tared teflon lid glass VOA
vial.
- Snap off the top of glass methanol ampule and add 10 ml pre-measured
methanol. Do not snap open with bare hands.
- Inspect soil/methanol mixture. Methanol must cover the soil. If not,
add another 10 ml, then add more soil until methanol just covers the soil
and note volume of methanol on chain-of-custody.
- If soil is low density (e.g. "loamy"), add soil until methanol just
covers the soil.
- Replace cap on VOA vial. Make sure cap threads are clean, otherwise
leaking will occur.
- Collect some soil (without methanol) for dry weight measurement. *Use
plastic flip-top bottle*
- Fill out chain of custody form with Sample ID, Date of Sampling, and
Client Info.
- Ship or deliver samples to lab (on ice). Keep samples cool (< 4EC or <
40E F) and ship to lab ASAP. Samples must be analyzed within 14 days.
|
White Water Associates
429 River Lane
Amasa, MI 49903 |
For any questions call:
Bette Premo
906-822-7889 |
|